Closed-loop in Adults With Type 2 Diabetes

NARECRUITING

The main objective of this study is to determine the efficacy, safety and utility of fully closed-loop glucose control in the home setting in adults with type 2 diabetes (T2D). This study builds on previous and on-going studies of closed-loop systems that have been performed in Cambridge in adults with type 2 diabetes in the inpatient and in the home setting and in children and adults with type 1 diabetes. This is an open-label, multi-national, multi-centre, randomised, single-period parallel study, involving a run-in period followed by a 26-week intervention period during which glucose levels will be controlled either by a fully closed-loop system or by participants usual insulin therapy with continuous glucose monitoring.

A total of up to 224 adults with type 2 diabetes using insulin will be recruited through outpatient diabetes clinics, primary care centres, social media advertising and other established methods at participating centres. Participants will receive appropriate training in the safe use of the study devices. The primary outcome is the between group difference in HbA1c at 26 weeks.

Other key outcomes include the time spent with glucose levels within, above and below the target glucose range (3. 9-10. 0mmol/L) and mean sensor glucose as recorded by CGM over the 26 weeks.

Insulin requirements, body weight, renal and liver function will also be compared. Safety evaluation comprises severe hypoglycaemic episodes, and other adverse and serious adverse events. Human factors outcomes include CGM \& closed-loop usage, questionnaires and semi-structured interviews.

Study details:

Purpose of clinical trial:. To determine the efficacy, safety and utility of fully closed-loop insulin delivery over 26 weeks in the home setting in adults with type 2 diabetes. Study objectives:.

To determine the efficacy, safety and utility of fully closed-loop insulin delivery over 26 weeks in the home setting in adults with type 2 diabetes. 1. EFFICACY: The objective is to assess the ability of fully closed-loop insulin delivery to improve glucose control as measured by HbA1c (primary endpoint) and sensor glucose metrics.

2. SAFETY: The objective is to evaluate the safety of fully closed-loop insulin delivery in terms of episodes and severity of hypoglycaemia, and nature and severity of other adverse events. 3.

UTILITY: The objective is to determine the acceptability and duration of use of the CGM and closed-loop system. 4. HUMAN FACTORS: The objective is to assess cognitive, emotional, and behavioural characteristics of participants and their response to the closed-loop system using validated questionnaires and semi-structured interviews.

Participating clinical centres:. UK - Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust. - Imperial College Healthcare NHS Trust, London.

\- Manchester Royal Infirmary, Manchester University NHS Foundation Trust. \- King's College Hospital, King's College Hospital NHS Foundation Trust, London. \- Guy's and St Thomas' NHS Foundation Trust.

\- Norfolk and Norwich University Hospital, Norfolk and Norwich University Hospitals NHS Foundation Trust. \- University Hospitals of Leicester NHS Trust. Switzerland.

\- Inselspital, Bern University Hospital, Bern. France. \- Centre Hospitalier Universitaire (CHU) de Toulouse.

Germany. \- Medical Center - University of Freiburg. Austria.

\- Medical University of Graz, Graz. Czech Republic. \- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague.

Sample Size:. 224 participants (112 per group) will be randomised. Recruitment will target a minimum quota of 25% of participants using basal insulin and a minimum quota of 60% of participants using multiple daily insulin injections.

Maximum duration of study for a subject: 30 weeks. Recruitment:. Participants will be recruited through outpatient diabetes clinics, primary care centres, social media advertising or other established methods at participating centres.

Consent:. Participants will be asked to provide written informed consent. Baseline Assessment:.

Eligible participants will undergo baseline evaluation involving talking a medical history including demographics, height/weight, waist hip ratio and blood pressure measurement and blood samples for HbA1c, fasted lipid profile, renal and liver function. A urine albumin-creatinine ratio (ACR) will be performed, along with a urine pregnancy test in females of child-bearing age. Human factors questionnaires will be completed and a masked glucose sensor will be applied.

Run-in Period:. During a 2-3 week run-in period, participants will use their usual insulin therapy and wear a masked CGM system. At the end of the run-in period, for compliance, at least 10 days of CGM data needs to be recorded.

CGM data during the run-in period will be used to assess baseline glucose control before the start of the intervention phase. Randomisation:. Eligible participants will be randomised in a 1:1 ratio using central randomisation software to fully closed-loop or standard insulin therapy with CGM for 26 weeks.

Randomisation will be stratified by site and baseline HbA1c. Fully closed loop insulin delivery (intervention arm):. Following randomisation, participants in the closed-loop group will receive training on the study CGM, study insulin pump and closed-loop App during a 1-2 hour outpatient session.

Competency on the use of the closed-loop system will be evaluated. Further training may be delivered as required. Participants will be advised to use the closed-loop system for the next 26 weeks.

Standard insulin therapy with CGM (control arm):. Following randomisation, participants in the control group will use their usual insulin therapy and the study CGM. Training on the use of the CGM will be provided.

Participants will use standard insulin therapy and CGM for the next 26 weeks. 3 month study visit: Weight, waist hip ratio and blood pressure will be measured and a blood sample will be taken for measurement of HbA1c, fasted lipid profile, renal and liver function. Data from the closed-loop system and CGM system will be reviewed.

Human factors questionnaires will be completed. End of study assessments:. Weight, waist hip ratio and blood pressure will be measured and a blood sample will be taken for measurement of HbA1c, fasted lipid profile, renal and liver function.

Urinary ACR will be measured. Human factors questionnaires will be completed and a subset of participants will participate in interviews. Study devices will be returned and participants will resume their usual insulin therapy and standard glucose monitoring.

Procedures for safety monitoring during trial:. Standard operating procedures for monitoring and reporting of all adverse events and adverse device events will be in place, including serious adverse events (SAE), serious adverse device effects (SADE) and specific adverse events (AE) such as severe hypoglycaemia. A data safety and monitoring board (DSMB) will be informed of all serious adverse events and any unanticipated serious adverse device effects that occur during the study and will review compiled adverse event data at periodic intervals.

Criteria for withdrawal of subjects on safety grounds:. A participant may terminate participation in the study at any time without necessarily giving a reason and without any personal disadvantage. An investigator can stop the participation of a subject after consideration of the benefit/risk ratio.

Possible reasons are:. * Participant is unable to demonstrate safe use of study devices as judged by the investigator. * Serious adverse events.

* Significant protocol violation or non-compliance. * Decision by the investigator, or the Sponsor, that termination is in the participant's best medical interest. * Pregnancy, planned pregnancy, or breast feeding.

* Allergic reaction to insulin or severe allergic reaction to adhesive surface of infusion set or glucose sensor. * Technical grounds (e. g.

participant relocates).

Eligibility criteria

Researchers look for people who fit a certain description, called eligibility criteria. See if you qualify.

Inclusion criteria

  1. Aged 18 years and older
  2. Type 2 diabetes diagnosed for at least 12 months
  3. Established on an SGLT2 inhibitor and/or GLP-1 receptor agonist for at least 3 months, or have been offered these therapies previously.
  4. Treatment with insulin therapy for at least 6 months
  5. HbA1c ≤ 15% (140 mmol/mol) analysis from local laboratory or equivalent
  6. Willing to wear study devices and follow study instructions
  7. Capacity to consent to participate in the study

Exclusion criteria

  1. Type 1 diabetes
  2. Current use of insulin pump
  3. Current use of any closed-loop system
  4. Any physical/psychological disease or medication(s) likely to interfere with the conduct of the study and interpretation of the study results, as judged by study clinician
  5. Known or suspected allergy against insulin
  6. Medically documented allergy towards the adhesive
  7. Pregnancy, planned pregnancy, or breast feeding
  8. Severe visual impairment
  9. Severe hearing impairment
  10. Medically documented allergy towards the adhesive (glue) of plasters
  11. Serious skin diseases located at places of the body, which potentially are possible to be used for localisation of the glucose sensor
  12. Illicit drugs abuse
  13. Prescription drugs abuse
  14. Alcohol abuse

Eligibility

Age eligible for study : NA

Healthy volunteers accepted : No

Gender eligible for study: ALL

Things to know

Study dates

Study start:

Primary completion:

Study completion finish:

study type

Study type

TREATMENT

phase

Phase

    NA

trial

Study ID

NCT06579404

Intervention or treatment

DEVICE: CamAPS HX

OTHER: Standard insulin therapy with glucose sensor

Conditions

  • Type 2 Diabetes Treated With Insulin
  • Condition: Type 2 Diabetes Treated With Insulin

  • DEVICE: CamAPS HX and other drugs

  • Melbourne, Australia

  • Sponsor: University of Cambridge

You may be eligible to participate in this trial based on your search. Check eligibility by answering some questions.

Are you running this trial?

If you're a clinic or sponsor, you can claim this study

Research sites nearby

Closest Location:

University of Melbourne

Select from list below to view details:

  • University of Melbourne

    Melbourne, Australia

Loading map...

Who is running the clinical trial?

UoC

University of Cambridge

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Participant Group/ArmIntervention/Treatment
EXPERIMENTAL: Fully closed-loop insulin delivery (CamAPS HX)
  • The automated closed loop system (CamAPS FX) will consist of:
  • * YpsoPump insulin pump (Ypsomed, Burgdorf, Switzerland)
  • * FreeStyle Libre 3 glucose sensor (Abbott Diabetes Care, CA, USA)
  • * Smartphone hosting CamAPS HX app with the Cambridge model predictive control algorithm
  • * Cloud upload system to review CGM/insulin data.
  • Participants will use the fully closed-loop system for 26 weeks at home
Device: CamAPS HX
    ACTIVE_COMPARATOR: Standard insulin therapy with glucose sensor
    • Usual insulin therapy and FreeStyle Libre 3 glucose sensor (Abbott Diabetes Care, CA, USA) for 26 weeks at home.
    Other: Standard insulin therapy with glucose sensor

      What is the study measuring?

      Primary Outcome

      MeasureDescriptionTime Frame
      Glycated haemoglobin (HbA1c) at 26 weeksCentralised measurement of HbA1cat 26 weeks

      Secondary Outcome

      MeasureDescriptionTime Frame
      Proportion of time spent in target glucose range (3.9 to 10.0mmol/L)Sensor glucose metric measured as a %over 26 weeks
      Mean glucose (mmol/L)Sensor glucose metric measured in mmol/Lover 26 weeks
      Proportion of time spent above target glucose (>10.0mmol/l)Sensor glucose metric measured as a %over 26 weeks
      Proportion of time spent below target glucose (<3.9mmol/L)Sensor glucose metric measured as a %over 26 weeks
      Standard deviation of sensor glucoseSensor glucose metric measured in mmol/Lover 26 weeks
      Coefficient of variation of sensor glucoseSensor glucose metric measured as a %over 26 weeks
      Proportion of time spent below target glucose (<3.5mmol/L)Sensor glucose metric measured as a %over 26 weeks
      Proportion of time spent below target glucose (<3.0mmol/L)Sensor glucose metric measured as a %over 26 weeks
      Proportion of time spent above target glucose (>13.9mmol/l)Sensor glucose metric measured as a %over 26 weeks
      Proportion of time spent above target glucose (>16.7mmol/l)Sensor glucose metric measured as a %over 26 weeks
      Proportion of time spent above target glucose (>20.0mmol/l)Sensor glucose metric measured as a %over 26 weeks
      Proportion of participants with HbA1c <7.0% [53mmol/mol] (%)Binary metric of HbA1cat 26 weeks
      Proportion of participants with HbA1c <7.5% [58mmol/mol] (%)Binary metric of HbA1cat 26 weeks
      Total daily insulin doseMeasured in units/dayover 26 weeks
      Body weightMeasured in kilogramsat 26 weeks
      Waist hip ratioRatio26 weeks
      Body Mass Index (BMI)Measured in kg/m226 weeks
      Fasted lipid profileMeasured in mmol/L26 weeks
      Renal functionRenal function as measured by serum creatinine26 weeks
      Renal functionRenal function as measured by estimated Glomerular Filtration Rate26 weeks
      Renal functionRenal function as measured by urinary albumin creatinine ratio26 weeks
      Liver functionLiver function as measured by FIB4 index26 weeks
      Liver functionLiver function as measured by alanine transaminase (ALT)26 weeks
      Liver functionLiver function as measured by aspartate transaminase (AST)26 weeks
      Liver functionLiver function as measured by alkaline phosphatase (ALP)26 weeks
      Liver functionLiver function as measured by gamma-glutamyl transferase (yGT)26 weeks
      Liver functionLiver function as measured by serum bilirubin26 weeks
      Liver functionLiver function as measured by albumin and FIB4 index26 weeks
      Are you running this trial?If you're a clinic or sponsor, you can claim this study.

      References

      Clinical Trials Gov: Closed-loop in Adults With Type 2 Diabetes

      Other trials to consider

      Loading suggested trials...

      Top searched conditions